Commissioning - Page 20
A Frost thermostat is fitted which will bring the appliance
on when the local temperature around the appliance
falls below 5 °C The appliance will shut down when the
temperature of the system water has been raised by
approximately 10 °C
The appliance is protected provided the mains light is
illuminated and the boiler switch is set to On,
irrespective of the settings of any external controls.
Note: the Frost thermostat will operate with the central
heating switch in any position therefore when leaving the
property in cold weather for extended periods, the boiler
will be protected even when the switch is set to Off (Mid
position).
Note: While the appliance is being used to provide hot
water at any draw off point, the central heating will not
operate. When hot water is no longer required the
appliance will automatically revert to central heating.
3.9 Complete the Installation
After completion of installation and commissioning of the
system re-fit the white front case.
The installer should hand over to the User by the
following actions:
1. Explain to the Householder where to find the User's
Guide and his/her responsibilities under the 'Gas Safety
(Installation and Use) Regulations 1994. (As Amended)'.
2. Explain and demonstrate the lighting and shutting down
procedures.
3. Demonstrate the operation of the boiler including the
use and adjustment of all system controls. This then
ensures the greatest possible fuel economy consistent
with household requirements of both heating and hot
water consumption. Advise the User of the precautions
necessary to prevent damage to the system, and to the
building, in the event of the system remaining
inoperative during frost conditions.
4. Explain the function and the use of the boiler switch,
central heating switch and Reset button.
5. Explain and demonstrate the function of time and
temperature controls, external frost thermostat (if fitted)
and radiator valves, etc. for the economic use of the
system.
6. If a Time Control is fitted (internal or external), then draw
attention to the timer 'User Instructions' and hand them
to the householder.
7. Stress the importance of regular servicing by a qualified
Heating Engineer and that a comprehensive service
should be carried out AT LEAST ONCE A YEAR.
8. An internal frost thermostat is fitted to the appliance, it
must be explained that the Boiler switch must be in the
On position (with the mains light illuminated) to provide
protection of the appliance, if it is not to be used during
winter periods.
Note: the Frost thermostat will operate with the central
heating switch in any position therefore when leaving the
property in cold weather for extended periods, the boiler will
be protected even when the switch is set to Off (Mid
position).